Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 38
Filter
1.
Journal of Peking University(Health Sciences) ; (6): 548-552, 2023.
Article in Chinese | WPRIM | ID: wpr-986888

ABSTRACT

OBJECTIVE@#To analyze the cement flow in the abutment margin-crown platform switching structure by using the three-dimensional finite element analysis, in order to prove that whether the abutment margin-crown platform switching structure can reduce the inflow depth of cement in the implantation adhesive retention.@*METHODS@#By using ANSYS 19.0 software, two models were created, including the one with regular margin and crown (Model one, the traditional group), and the other one with abutment margin-crown platform switching structure (Model two, the platform switching group). Both abutments of the two models were wrapped by gingiva, and the depth of the abutment margins was 1.5 mm submucosal. Two-way fluid structure coupling calculations were produced in two models by using ANSYS 19.0 software. In the two models, the same amount of cement were put between the inner side of the crowns and the abutments. The process of cementing the crown to the abutment was simulated when the crown was 0.6 mm above the abutment. The crown was falling at a constant speed in the whole process spending 0.1 s. Then we observed the cement flow outside the crowns at the time of 0.025 s, 0.05 s, 0.075 s, 0.1 s, and measured the depth of cement over the margins at the time of 0.1 s.@*RESULTS@#At the time of 0 s, 0.025 s, 0.05 s, the cements in the two models were all above the abutment margins. At the time of 0.075 s, in Model one, the gingiva was squeezed by the cement and became deformed, and then a gap was formed between the gingiva and the abutment into which the cement started to flow. In Model two, because of the narrow neck of the crown, the cement flowed out from the gingival as it was pressed by the upward counterforce from the gingival and the abutment margin. At the time of 0.1 s, in Model one, the cement continued to flow deep inside with the gravity force and pressure, and the depth of the cement over the margin was 1 mm. In Model two, the cement continued to flow out from the gingival at the time of 0.075 s, and the depth of the cement over the margin was 0 mm.@*CONCLUSION@#When the abutment was wrapped by the gingiva, the inflow depth of cement in the implantation adhesive retention can be reduced in the abutment margin-crown platform switching structure.


Subject(s)
Finite Element Analysis , Cementation/methods , Gingiva , Crowns , Dental Abutments , Dental Cements , Dental Stress Analysis
2.
Chinese Journal of Stomatology ; (12): 451-456, 2023.
Article in Chinese | WPRIM | ID: wpr-986093

ABSTRACT

About 8 dental schools were founded by Chinese dentists during modern times (1909-1949) in China. Only one still worked after the founding of the People's Republic of China, which was one of the three dental schools founded by dentist Situ Bo. There were no systematic researches on Situ Bo's participation in dentistry education. This paper analyzes the founder's experience in dentistry and in the two schools he founded at the beginning, focusing on the background and process of the schools' construction, management, teaching, teachers and students training, etc. The results show that the establishment of the first two dental schools have laid important foundation for the establishment and development of Shanghai Dental College by the reserve of trained professional teachers and accumulated valuable experience in running schools. The systematic review of this history will help us better understand the establishment and development of Shanghai Dental College and the efforts in dentistry education made by dentists growed up in modern China, as well as the early development process of stomatology.

3.
Journal of Peking University(Health Sciences) ; (6): 108-113, 2023.
Article in Chinese | WPRIM | ID: wpr-971281

ABSTRACT

OBJECTIVE@#To predict the learning curve of tooth preparation for all ceramic crowns of maxillary central incisors on phantom head simulators for graduate students participating in standardized dental resident training based on the modified Wright learning curve model, then to analyze and applicate the learning curve.@*METHODS@#Twelve graduate students participating in standardized dental resident training were selected to prepare the resin maxillary central incisors on phantom head simulators for all ceramic crowns 4 times. The results of preparation were evaluated by 3 prosthetic experts with at least 10 years' experience focusing on the reduction, contour, taper, shoulder, finish line, margin placement, adjacent tooth injury, and preparation time for tooth preparation. The learning rate of tooth preparation was calculated by scores of tooth preparation of 4 times. The learning curve of tooth preparation was predicted based on the modified Wright learning curve model. According to the criteria of standardized training skill examinations for dental residents in Beijing, 80 was taken as the qualified standard score. The minimum training times for tooth preparation to satisfy the qualified standard score (80) was calculated, to analyze the characteristics of learning curve and evaluate the effectiveness of tooth preparation.@*RESULTS@#The scores of 4 tooth preparation were 64.03±7.80, 71.40±6.13, 74.33±5.96, and 75.98±4.52, respectively. The learning rate was (106±4)%, which showed the learning curve an upward trend. There were no significant differences between the qualified standard score and the predicted scores of tooth preparation from the 5th preparation to the 13th preparation (P > 0.05). The predicted score of the 14th preparation was higher than the qualified standard score (P < 0.05).@*CONCLUSION@#The trend of the learning curve of tooth preparation for all ceramic crowns of maxillary central incisors on phantom head simulators for graduate students participating in standardized dental resident training is upward, which predicts the minimum training times higher than the qualified standard score is 14 times.


Subject(s)
Humans , Tooth Preparation, Prosthodontic/methods , Incisor , Learning Curve , Crowns , Tooth Preparation , Ceramics , Dental Porcelain , Dental Prosthesis Design
4.
Chinese Journal of Stomatology ; (12): 174-179, 2023.
Article in Chinese | WPRIM | ID: wpr-970771

ABSTRACT

Professor Mao Xiejun wrote a report about dental education of China in 1935. From 1948 to 1950, he published three articles containing the educational idea of "developing dentistry into stomatology". When he served as the director of the Faculty of Dentistry of Peking University Medical School in July 1950, he proposed to rename the Faculty of Dentistry into the Faculty of Stomatology,which were approved by the Ministry of Health and the Ministry of Education of the People's Republic of China in one month. The Chinese Medical Association established the Society of Stomatology the next year. Later, dentistry was successively changed into stomatology, and medical content was integrated into dental education, which was of great significance and far-reaching influence. During the developments of the thought of stomatological education in China, Professor Mao Xiejun evidently played a pivotal role. In this paper, the formation process of the thoughts of stomatological education related to professor Mao Xiejun's contribution is elucidated through studying the archives, personal letters, and historical documents, so as to enrich the researches on the history of stomatology in China and to facilitate better understanding and promoting the development of stomatology.


Subject(s)
Humans , Oral Medicine/education , Education, Dental , China , Universities
5.
Chinese Journal of Stomatology ; (12): 272-279, 2022.
Article in Chinese | WPRIM | ID: wpr-935861

ABSTRACT

Objective: To compare the clinical performance of posterior single implant-supported monolithic zirconia crowns fabricated by full digital workflow and that of those fabricated by conventional workflow. Methods: This is prospective clinical research. Thirty-five patients who participated in a previous study during August 2017 to October 2018 at Department of Prosthodontics, Peking University School and Hospital of Stomatology were included in this 3-year follow-up study. The 35 patients, 17 females and 18 males, aged (49.0±15.4) years (24-86 years old), was allocated into two groups. In the full digital workflow group, intraoral scanning was taken immediately after implant placement, and a full zirconia implant crown was fabricated using model-free computer aided design/computer aided manufacturing (CAD/CAM) procedure (n=14). In the conventional group, a conventional impression was taken 3 months after implant placement and the stone model was produced. A full zirconia implant crown was fabricated using conventional model-based procedure (n=21). Three years following crown delivery, all the prostheses were evaluated in the aspect of color, surface roughness, contour and marginal integrity using modified US Public Health Service criteria (MUSPHS criteria). The soft and hard tissue around implant was evaluated using modified plaque index, probing depth (PD), number of implants with bleeding on probing, marginal bone loss (MBL). The biological and mechanical complication were also recorded. Statistical analysis was performed using independent samples t test, Mann-Whitney U test and Fisher's exact test. Results: The total survival rate of prosthesis and implant was 100% (35/35). No significant difference in MUSPHS criteria ratings on color, surface roughness, contour and marginal integrity of these crowns were found between the full digital workflow group and the conventional group (P>0.05). Sixteen out of the 35 crowns had a contour score of B due to loss of interproximal contact. Ten out of the 35 crowns had the screw hole sealing resin sinking or falling off, four in the full digital workflow group and six in the conventional group. There was no significant difference in the rate of prostheses mechanical complications between the two groups (P=1.000). For all the implants, there was no significant difference in MBL, PD, the modified plaque index, and number of implants with bleeding on probing between the two groups (U=119.50,133.00,142.50, t=-0.53, P>0.05). Conclusions: The clinical performance of implant-supported posterior single monolithic zirconia crowns fabricated by full digital workflow was stable. There was no significant difference in the clinical performance of the single implant crowns between the full digital workflow group and the conventional group.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Crowns , Follow-Up Studies , Prospective Studies , United States , Workflow , Zirconium
6.
Chinese Journal of Stomatology ; (12): 101-106, 2022.
Article in Chinese | WPRIM | ID: wpr-935836

ABSTRACT

In dental esthetic rehabilitation, patients pay great attention to the rehabilitative esthetic effect before teeth preparation, and this is also an important content of doctor-patient communication. Along with the development and combined application of intraoral scan, three-dimensional (3D) face scan, digital design, numerical control machining and 3D printing technology, digital technology is gradually applied to the virtual simulated design before irreversible operation in dental esthetic rehabilitation. Digital technology can be used in dentistry to simulate the esthetic outcome in advance, to assist communication among the dentists, patients and dental technicians, and to realize satisfactory outcome in the final restorations precisely, which, as a result, increases the clinical satisfaction. This review focuses on the application of digital virtual simulated design technology in dental esthetic rehabilitation, analyzes the current research development, deficiency and future prospects, so as to provide guidance for clinical diagnosis and treatment.


Subject(s)
Humans , Computer-Aided Design , Esthetics, Dental , Face , Printing, Three-Dimensional , Tooth Preparation
7.
Journal of Peking University(Health Sciences) ; (6): 193-199, 2022.
Article in Chinese | WPRIM | ID: wpr-936134

ABSTRACT

OBJECTIVE@#To automatically construct lips symmetry reference plane (SRP) based on posed smile, and to evaluate its advantages over conventional digital aesthetic design.@*METHODS@#Eighteen subjects' three-dimensional facial and dentition data were gathered in this study. The lips SRP of experimental groups were used with the standard weighted Procrustes analysis (WPA) algorithm and iterative closest point (ICP), respectively. A reference plane defined by experts based on regional ICP algorithm, served as the truth plane. The angle error values between the lips SRP of WPA algorithm in the experimental groups and the truth plane were evaluated in this study, and the lips SRP of ICP algorithm of the experimental groups was calculated in the same way. The lips SRP based on posed smile as a reference for aesthetic design and evaluate preliminary clinical application.@*RESULTS@#The average angle error between the lips SRP of WPA algorithm and the truth plane was 1.78°±1.24°, which was smaller than that between the lips SRP of ICP and the truth plane 7.41°±4.31°. There were significant differences in the angle errors among the groups (P < 0.05). In the aesthetic design of anterior teeth, automatically constructing the lips SRP of WPA algorithm based on posed smile and the original symmetry plane by re-ference compared with the prosthetic design, the subjects' scores on the lips SRP of WPA algorithm based on posed smile (8.48±0.57) were higher than those on the original symmetry plane (5.20±1.31).@*CONCLUSION@#Automatically constructing the lips SRP of WPA algorithm based on posed smile was more accurate than ICP algorithm, which was consistent with the truth plane. Moreover, it can provide an important reference for oral aesthetic diagnosis and aesthetic analysis of the restoration effect. In the aesthetic design of anterior teeth, automatically constructing the lips SRP of WPA algorithm based on posed smile can improve the patients' satisfaction in esthetic rehabilitation.


Subject(s)
Humans , Esthetics, Dental , Lip , Smiling , Tooth , Workflow
8.
Journal of Peking University(Health Sciences) ; (6): 105-112, 2022.
Article in Chinese | WPRIM | ID: wpr-936120

ABSTRACT

OBJECTIVE@#To compare the retentions of different designs of cobalt-chromium (Co-Cr), pure titanium (CP Ti), and titanium alloy (Ti-6Al-4V) removable partial denture (RPD) circumferential clasps manufactured by selective laser melting (SLM) and to analyze the stress distribution of these clasps during the removal from abutment teeth.@*METHODS@#Clasps with clasp arm size A (1.9 mm width/1.1 mm thickness at the body and 0.8-taper) or B (1.2 times A) and 0.25 mm or 0.50 mm undercut engagement were modeled on a prepared first premolar die, named as designs A1, A2, A3, and A4, respectively. The density and elastic modulus of SLM-built Co-Cr, CP Ti, and Ti-6Al-4V were measured and given to different groups of clasps. The density, elastic modulus, and Poisson ' s ratio of enamel were given to the die. The control group was the cast Co-Cr clasp with design A1, to which the density and elastic modulus of cast Co-Cr alloy were given. The Poisson's ratio of all metals was 0.33. The initial 5 N dislodging force was applied, and the maximum displacement of the clasp along the insertion path was computed. The load was reapplied with an increment of 5 N than in the last simulation until the clasp was completely dislodged. The retentive force range of different groups of clasps was obtained. The retentive forces of the SLM-built Co-Cr, CP Ti, and Ti-6Al-4V clasps with equivalent computed retentive force range to the control group were validated through the insertion/removal experiment. The von Mises stress distributions of these three groups of SLM-built clasps under 15 N loads were analyzed.@*RESULTS@#SLM-built Co-Cr, CP Ti, and Ti-6Al-4V clasps with designs B1 or B2, and Co-Cr clasps with design A2 had higher retentive forces than those of the control group. SLM-built CP Ti and Ti-6Al-4V clasps with design A1 had lower retentive forces than those of the control group. SLM-built Co-Cr clasp with design A1 and SLM-built CP Ti and Ti-6Al-4V clasps with design A2 had equivalent retentive forces to those of the control group. The insertion/removal experiment showed that the measured retentive forces of these three groups of SLM-built clasps were (21.57±5.41) N, (19.75±4.47) N, and (19.32±2.04) N, respectively. No statistically significant measured retentive force difference was found among these three groups of SLM-built clasps (P>0.05). The maximum von Mises stress of these three groups of SLM-built clasps exceeded their responding yield strength except for the Ti-6Al-4V one.@*CONCLUSION@#SLM-built Co-Cr circumferential clasps had higher retention than CP Ti and Ti-6Al-4V ones with the same clasp arm size and undercut engagement. The retention of SLM-built circumferential clasps could be adjusted by changing the undercut engagement and clasp arm size. If SLM-built circumferential clasps are used in clinical practice, the Ti-6Al-4V clasp with clasp arm size A and 0.50 mm undercut engagement is recommended considering the long-term use of RPD in the patient's mouth.


Subject(s)
Humans , Chromium Alloys , Dental Clasps , Denture Retention , Denture, Partial, Removable , Finite Element Analysis , Lasers , Titanium
9.
Journal of Peking University(Health Sciences) ; (6): 406-412, 2021.
Article in Chinese | WPRIM | ID: wpr-942195

ABSTRACT

OBJECTIVE@#To compare the differences and indications of three evaluation methods for fitness evaluation of removable partial denture (RPD).@*METHODS@#A RPD was fabricated and seated on the stone cast of a partially edentulous mandible, and the spaces between RPD and stone cast were recorded with polyvinyl siloxane (PVS) impression material forming PVS replicas. Using cross sectional measurement, the average thicknesses of PVS replicas were measured under stereomicroscope with different numbers of selected measuring points in the denture base, major connector, occlusal rest of the RPD, and the average thicknesses of the PVS replicas measured with different numbers of measuring points were compared using one-way analysis of variance (ANOVA) and independent sample t test. Three kinds of method, including cross sectional measurement, three-dimensional analysis on the stone cast, and three-dimensional analysis on the polyether cast, were applied to measure the average thicknesses of the PVS replicas, and the average thicknesses of the PVS replicas measured by these three evaluation methods were compared with ANOVA.@*RESULTS@#For cross sectional measurement, statistically significant differences were found in the average thicknesses of the PVS replicas in the denture base and the major connector among the different numbers of measuring points (P < 0.05), but no differences were found in the average thicknesses of the PVS replicas in the occlusal rest (P>0.05). There were significant differences among the average thicknesses of the PVS replicas measured by these three evaluation methods in each component of the RPD (P < 0.01). The average thickness measured by three-dimensional analysis on the stone cast and three-dimensional analysis on polyether cast were smaller than that measured by cross sectional measurement (P < 0.05). And there were no differences between the average thicknesses of PVS replicas measured by three-dimensional analysis on stone cast and three-dimensional analysis on polyether cast (P>0.05).@*CONCLUSION@#For cross sectional measurement, the average thickness of the PVS replicas was influenced by the number of measuring points, and the measurement accuracy of cross sectional measurement was not reliable enough. Three-dimensional analysis on stone cast which is suitable for evaluation in vitro and three-dimensional analysis on polyether cast which is suitable for evaluation in vivo can evaluate the fitness of RPD more comprehensively and effectively than that of cross sectional measurement.


Subject(s)
Computer-Aided Design , Cross-Sectional Studies , Denture, Partial, Removable , Exercise , Research Design
10.
Journal of Peking University(Health Sciences) ; (6): 402-405, 2021.
Article in Chinese | WPRIM | ID: wpr-942194

ABSTRACT

OBJECTIVE@#To evaluate the effects of different edge compensation angles on the fracture strength of multilayer zirconia all-ceramic crowns and traditional uniform zirconia all-ceramic crowns.@*METHODS@#The resin tooth preparation specimen of the mandibular first molar with a knife-edge was fabricated. A 3D digital model of the specimen was obtained by scanning it with a 3D dental model scanner. The 3D digital model was imported into computer aided design (CAD) software, and three 3D digital models of the full crown with the same surface shape are designed with the edge compensation angles of 30°, 45° and 60°, respectively. Then, the designed 3D digital model is imported into computer aided manufacturing (CAM) software. Three kinds of multilayer and homogeneous zirconia all-porcelain crowns with different edge compensation angles were fabricated, 10 each for a total of 60. The fracture load of each crown was measured under the electronic universal testing machine.@*RESULTS@#Fracture load of multilayer and uniform zirconia all-ceramic crowns, (4 322.86±610.07) N and (5 914.12±596.80) N in the 30° group, (5 264.82±883.76) N and (5 220.83±563.38) N in the 45° group and (4 900.42±345.41) N and (5 050.22±560.24) N in the 60° group, respectively. The fracture load of multi-layer zirconia all-ceramic crowns in the 30° group was significantly lower than that of homogeneous zirconia all-ceramic crowns(P < 0.05); there was no statistical significance in 45° group and 60° group(P>0.05). In the multi-layer zirconia all-ceramic crowns: the fracture load of the 30° group was significantly lower than that of the 45° group (P < 0.05); there was no significant difference between the 30° group and the 60° group, the 45° group and the 60° group (P>0.05).In uniform zirconia full crown group: the 30° group was higher than the 45° group, the 30° group was higher than the 60° group (P < 0.05), and there was no significant difference between the 45° group and the 60° group (P>0.05).@*CONCLUSION@#The fracture loads of three kinds of uniform and multilayer zirconia all ceramic crowns with different edge compensation angles can meet the clinical requirements. A smaller edge compensation angle is recommended when using traditional zirconia all-ceramic crowns, while 45° is recommended when using multi-layer zirconia all-ceramic crowns.


Subject(s)
Ceramics , Computer-Aided Design , Crowns , Dental Porcelain , Dental Prosthesis Design , Dental Restoration Failure , Dental Stress Analysis , Flexural Strength , Materials Testing , Zirconium
11.
West China Journal of Stomatology ; (6): 1-8, 2021.
Article in English | WPRIM | ID: wpr-878402

ABSTRACT

Digital technologies use high-precision three-dimensional scanning, intelligence-aided design software, and multi-axis numerical control milling or 3D printing, which can produce restorations with reliable precision and suitable function. However, the development of digital technologies in the field of complete denture restoration has been slow due to the complexity of prosthesis. This review article introduces the current research status and clinical applications of digital complete dentures in prosthodontic clinics and dental laboratories to provide beneficial references to prosthodontists and dental technicians.


Subject(s)
Computer-Aided Design , Denture, Complete , Printing, Three-Dimensional
12.
Journal of Peking University(Health Sciences) ; (6): 83-87, 2020.
Article in Chinese | WPRIM | ID: wpr-942145

ABSTRACT

OBJECTIVE@#To compare the registration accuracy of three-dimensional (3D) facial scans for the design of full-arch implant supported restoration by five methods and to explore the suitable registration method.@*METHODS@#According to the criteria, ten patients with maxillary edentulous jaw or end-stage dentition requiring implant supported restorations were enrolled in this study. A special rim with individual feature marks reflected appropriate occlusal relationship and esthetic characteristics was made for each patient. Both 3D facial scan data of natural laughter and with opener traction to expose the teeth or occlusal rim of each patient were acquired by facial scan and input to the digital analysis software Geomagic Qualify 2012. The dataset was superimposed by five different methods: seven facial anatomical landmark points alignment, facial immobile area alignment (forehead and nasal area), facial anatomical landmark points and immobile area combining alignment, facial feature points alignment, facial and intraoral feature points alignment with the same local coordinate system. The three-dimensional deviation of the same selected area was calculated, the smaller the deviation, the higher the registration accuracy. The 3D deviation was compared among the three registration methods of facial anatomical landmark points, facial immobile area alignment and the combination of the above two methods. Friedman test was performed to analyze the difference among the three methods (α=0.05). The effect of the aid of the facial and intraoral feature points were evaluated. Paired t test were performed to analyze the difference (P<0.05).@*RESULTS@#The average three-dimensional deviation of the selected area after alignment with the facial anatomical landmarks was (1.501 2±0.406 1) mm, significantly larger than that of the facial immobile area best-fit alignment [(0.629 1±0.150 6) mm] and the combination of the two methods[(0.629 1±0.150 6) mm] (P < 0.001). The aid of the facial feature points could significantly reduce the deviation (t=1.001 3, P < 0.001). There was no significant statistical difference in the remaining groups.@*CONCLUSION@#The forehead area of the 3D facial scan can be exposed as much as possible. The establishment of facial characteristic landmark points and the use of the invariant area alignment can improve the accuracy of registration. It should be clinically feasible to apply three-dimensional facial scan to the design of full-arch implant supported restoration with the registration of the immobile area on the face especially the forehead area.


Subject(s)
Humans , Computer-Aided Design , Imaging, Three-Dimensional , Jaw, Edentulous/diagnostic imaging , Maxilla/diagnostic imaging , Radionuclide Imaging
13.
Journal of Peking University(Health Sciences) ; (6): 62-68, 2020.
Article in Chinese | WPRIM | ID: wpr-942142

ABSTRACT

OBJECTIVE@#To explore the preliminary application of "biocopy function" in digital technology of temporary crown in severe tooth attrition, so as to reduce the difficulty of final restoration adjustment in severe tooth wear cases, and save clinical time.@*METHODS@#Twelve patients aged between 40 and 65 years with severe tooth attrition were recruited in this study. The experimental group (6 cases, 3 females and 3 males) used the method of digital copy of temporary restoration shape when making the final restoration, and the control group (6 cases, 3 females and 3 males) used the traditional method to make the final restoration. The mean time of central occlusal adjustment and protrusive and lateral occlusal adjustment of each crown, the number of follow-up visits of the patients were recorded and statistically analyzed. The occlusal comfort of the first and the third months after wearing the prosthesis was evaluated by the patients, and the difference of the occlusal comfort of the final prosthesis made by the two methods was compared (the full score was 10 points). The occlusal adjustment time and occlusal comfort score were used as measurement data. Single sample t test was used. The number of follow-up visits was count data. Rank sum test was used for non-normal continuous variables.@*RESULTS@#The mean occlusal time of each crown adjustment in the experimental group was significantly lower than that in the control group (P < 0.01), and the median number of follow-up visits in the experimental group was lower than that in the control group (P < 0.01). The average occlusal comfort score of the experimental group was higher than that of the control group at the first time (P < 0.01). After three months of crown wearing, the median occlusal comfort score of the experimental group was higher than that of the control group (P < 0.05).@*CONCLUSION@#In the case of severe tooth attrition, it is feasible to use the "biocopy function" in the design software to design the final prosthesis, which is conducive to reduce the difficulty of adjustment and achieve predictable functional and aesthetic effects, which is of great significance to save clinical time and improve the accuracy of restoration.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Computer-Aided Design , Crowns , Tooth
14.
Journal of Peking University(Health Sciences) ; (6): 762-770, 2020.
Article in Chinese | WPRIM | ID: wpr-942074

ABSTRACT

OBJECTIVE@#To compare the clinical efficacy of a kind of complete dentures fabricated using computer aided design/computer aided manufacturing (CAD/CAM) workflow with that of the complete denture fabricated using conventional workflow.@*METHODS@#Twenty edentulous patients were included in this prospective, single-blind, self-controlled clinical trial. Two pairs of complete dentures were fabricated for each participant: one using the functional suitable denture (FSD) system with CAD/CAM, and the other using conventional fabrication workflow. In the final delivery appointment, the conventional dentures worn by the participant for 3 months at first. Then the participant swapped to wear digital denture for another 3 months. The patients' satisfaction and oral health related quality of life (OHRQoL) were measured using the visual analogue scale (VAS) and oral health impact profile (OHIP-20E) at baseline, 2 weeks, 1 month, 2 months, and 3 months following denture delivery. In addition, the masticatory efficiency of each pair of dentures was measured after three months adaptation period for each type of dentures.@*RESULTS@#The VAS scores of the twenty patients in FSD denture group on general satisfaction, ease of cleaning, ability to speak, esthetics, stability and oral health status on these six domains were higher than that of conventional denture group 3 months after delivery. While the VAS cores in FSD denture group on comfort, ability to chew and ability to chew up were the same as those of conventional denture group. But there was no significant difference (P>0.05). The VAS score on each domain in FSD denture group was higher than that of conventional denture group 3 months after delivery, three domains of which reached statistical significance (P < 0.05), involving functional limitation, psychological discomfort and total. The masticatory performance of the FSD denture (1.20±0.54) was slightly higher than that for the conventional denture (1.16±0.53), but the difference did not reach statistical significance (P=0.691).@*CONCLUSIONS@#The clinical efficacy of the FSD complete denture is comparable to that of the conventional complete denture. As for patient satisfaction and oral health related quality of life, FSD dentures received comparable scores as conventional complete dentures did.


Subject(s)
Humans , Denture, Complete , Patient Satisfaction , Prospective Studies , Quality of Life , Single-Blind Method , Treatment Outcome
15.
Journal of Peking University(Health Sciences) ; (6): 390-394, 2020.
Article in Chinese | WPRIM | ID: wpr-942017

ABSTRACT

Fabrication of conventional complete dentures involves a complex restoration method, requiring significant time and typically involving primary impressions, definitive impressions, jaw relation records, clinic try-in, and complete denture placement, which has been used for nearly a century without change. A novel digital system named Functionally Suitable Denture (FSD) was researched and developed so as to reduce clinical steps, operation difficulties and errors of complete denture restoration. It pioneered a unique diagnostic complete denture aided by computer aided design (CAD) & 3D printing, by which, the functional impression, jaw relation, and try-in (3 steps) were simplified to 1 step, thus the number of visits to the dentist was reduced by 2 times. Moreover, for the first time, it put forward a CAD software of template matching based on the expert design, which was an efficient and intelligent design scheme, and the excellent denture experts' experience and skills could be inherited and iterated. The system included the 3D scanner with appropriate accuracy and high efficiency, the CAD software, the special 3D printer and process software, and the innovative clinical operation process. The Patent Cooperation Treaty (PCT) patent international search report showed that all the 15 claims of the technology were of novelty, creativity and industrial utility. All the digital products were independently developed and made by Peking University School and Hospital of Stomatology, China. The design and manufacture process of denture prosthesis was fast, simple and accurate. At the same time, personalized functional and aesthetic matching of the patients after wearing prosthesis was realized. It effectively solved the global problems of "slow, difficult and inaccurate" of the traditional manual technology of complete denture, and brought good news to edentulous patients. Compared with the traditional complete denture treatment, FSD system has a wide range of applications for different types of edentulous patients, including those with severe resorption of the alveolar ridge or a high occlusal force. Furthermore, the low-cost of 3D printers, compared with expensive milling machines, may make the approach more accessible. This review describes that our research is related to the development of the FSD system, including multi-source data acquisition technology, three generations of complete denture design software, 3D printing systems of individual tray and complete denture pattern, the clinical and laboratory operation process of the FSD system.


Subject(s)
Humans , China , Computer-Aided Design , Creativity , Denture, Complete , Mouth, Edentulous
16.
Journal of Peking University(Health Sciences) ; (6): 187-192, 2020.
Article in Chinese | WPRIM | ID: wpr-941987

ABSTRACT

OBJECTIVE@#To explore the possibility of the Smile Lite MDP (Smile Lite Mobile Dental Photograph) portable dental photography system applying in anterior teeth aesthetic photography, and to provide the chance to simplify aesthetic photography process and facilitate communication among patients, dentists and dental technitians.@*METHODS@#The Smile Lite MDP photography system combined with the smartphone were used to photograph the front occlusal phase photos of anterior teeth. The photographic conditions including the color temperature parameter, the Smile Lite MDP light position and the intensity settings were explored. The best photographic conditions were chosen by blind evaluation within experienced dentists and technicians through the method of the visual analogue scale/score (VAS) evaluation, which went through statistical analysis to figure out the optimum photograghic conditions. Smile Lite MDP photography system was used to photograph the front occlusal phase photos of anterior teeth under the optimum parameter by different magnifications. The width/height ratio of the central incisor and the front width ratio of the upper anterior teeth in those photos were measured and calculated respectively. The accuracy of the anterior teeth photos taken by Smile Lite MDP photography system was analyzed based on the photographs taken by digital single lens reflex (DSLR) camera.@*RESULTS@#The optimum color temperature parameter of Smile Lite MDP portable camera system was 5 000 K, the optimum magnification was 4 times, the best light position was the side lights of Smile Lite MDP, the optimum intensity of lights was 2 grades. Photos taken by the optimum parameters won the highest score during the VAS evaluation and the result of statistical analysis had significant difference compared with other groups (P<0.05). When comparing the photos of the upper anterior teeth taken by the Smile Lite MDP portable photography system using 4 times magnification or by DSLR using the standard parameters, there was no significant difference neither in the width/hieght ratio of the central incisor nor in the front width ratio of the upper anterior teeth (P>0.05).@*CONCLUSION@#The Smile Lite MDP portable dental photography system applying in anterior teeth aesthetic analysis photography was capable to show the color and shape of anterior teeth in an accurate way by using the right photography parameters. Therefore, Smile Lite MDP portable dental photography system was considered to be a simple and easy photographic tool in clinical work.


Subject(s)
Humans , Esthetics , Esthetics, Dental , Incisor , Photography , Smiling
17.
Journal of Peking University(Health Sciences) ; (6): 107-112, 2020.
Article in Chinese | WPRIM | ID: wpr-941974

ABSTRACT

OBJECTIVE@#To study the visual sensitivity threshold of physician's naked eye to the difference of nasolabial angle in edentulous jaw patients, and to provide a reference value for the study of aesthetic evaluation of soft tissue profile for the difference of nasolabial angle that can be recognized by human eyes.@*METHODS@#Three-dimensional facial images of three edentulous patients with different diagnostic dentures introoral were obtained. Lateral screenshots of each patient's three-dimensional facial image with the same scale were obtained by using reverse engineering software (Geomagic studio 2014).The screenshot of the patient's three-dimensional facial image with suitable lip support (The suitable lip support was confirmed by both patients and prosthodontists who had clinical experience for more than 20 years) was taken as the reference picture, and the remaining pictures were grouped with it respectively. All the pictures were observed in random order by the subjects. Fifteen dentists were asked to judge the difference of nasolabial angle between the two pictures of each group on the computer screen. The difference of nasolabial angle between the two pictures in each group was measured and calculated. The ROC curve was drawn, and the best cut-off value was calculated as the visual sensitivity threshold.@*RESULTS@#The data of the 15 subjects were used to draw ROC curves separately. The maximum and minimum best cut-off values were 5.55 degrees and 3.12 degrees respectively. The ROC curve of the whole 15 subjects was drawn after data aggregation, and the best cut-off value was 5.36 degrees (AUC=0.84>0.5, P=0.000<0.05). When the difference of nasolabial angle was above 5.36 degrees, the subjects could recognize it effectively.@*CONCLUSION@#There is a visual limit in the observation of the nasolabial angle with the naked eye. In this study, a visual sensitivity threshold of 5.36 degrees for the difference of the nasolabial angle was obtained. The difference of nasolabial angle below this value can be regarded as no clinical significance. This result provides a reference value for human eyes to recognize the difference of nasolabial angle in soft tissue profile aesthetic evaluation. It can be applied to the aesthetic evaluation of soft tissue profile and can be used as the error level of related research with nasolabial angle as an index for accuracy evaluation.


Subject(s)
Humans , Esthetics , Face , Jaw, Edentulous , Lip , Nose , Visual Acuity
18.
Journal of Peking University(Health Sciences) ; (6): 1-9, 2020.
Article in Chinese | WPRIM | ID: wpr-941958

ABSTRACT

OBJECTIVE@#To identify the role of Tribbles pseudokinase 3 (TRIB3) during the process of adipogenic differentiation of human adipose-derived mesenchymal stem cells (hASCs), and to provide a new target and a novel idea for the application of hASCs in adipose tissue engineering and soft tissue regeneration.@*METHODS@#TRIB3-knockdown hASCs (shTRIB3) and TRIB3-overexpression hASCs (TRIB3-over) were established using lentivirus transfection technique. The transfection effect was estimated by the visible presence of green fluorescence as the expression of green fluorescent protein (GFP) in the transfected hASCs. The lentiviral transfection efficiency was examined by quantitative real-time polymerase chain reaction (qRT-PCR) and Western blot. After adipogenic induction, Oil Red staining and quantification, as well as qRT-PCR about several specific adipogenic markers were used to evaluate the adipogenic differentiation ability of hASCs.@*RESULTS@#In TRIB3-knockdown hASCs, the TRIB3 mRNA expression level decreased by about 84.3% compared with the control group (P<0.01), and the TRIB3 protein level also showed obvious reduction. Oppositely, in TRIB3-overexpression hASCs, the TRIB3 mRNA expression level increased by approximately 160% compared with the control group (P<0.01), and the TRIB3 protein level also showed a significant increase. These results indicated a successful construction of TRIB3-knockdown hASCs and TRIB3-overexpression hASCs. The Oil Red staining results showed that the down-regulation of TRIB3 significantly promoted lipid droplets formation in hASCs, consistent with Oil Red quantification. On the other hand, the up-regulation of TRIB3 suppressed lipid droplets formation in hASCs, consistent with Oil Red quantification. After adipogenic induction, adipogenesis-related genes, including peroxisome proliferator-activated receptor γ (PPARγ), cluster of differentiation 36 (CD36) and CCAAT/enhancer binding protein α (C/EBPα), were increased significantly in TRIB3-knockdown hASCs compared with the control group (P<0.01). Oppositely, PPARγ, CD36 and lipoprotein lipase (LPL) were significantly decreased in TRIB3-overexpression hASCs compared with the control group (P<0.01).@*CONCLUSION@#TRIB3 inhibited the adipogenic differentiation of hASCs. Knockdown of TRIB3 promoted the ability of adipogenesis of hASCs, while overexpression of TRIB3 inhibited the adipogenic differentiation of hASCs. Considering the important role of PPARγ in the adipogenis process, the molecular mechanism of the regulatory function of TRIB3 may be related with PPARγ signal pathway.


Subject(s)
Humans , Adipogenesis , Adipose Tissue , Cells, Cultured , Mesenchymal Stem Cells
19.
Journal of Peking University(Health Sciences) ; (6): 349-355, 2019.
Article in Chinese | WPRIM | ID: wpr-941819

ABSTRACT

OBJECTIVE@#To design and fabricate edentulous custom trays by chair-side computer-aided design and 3-dimensional printing (CAD/3DP) system of independent research and development and to evaluate their clinical effects based on prosthodontists'satisfaction using the visual analogue scale (VAS).@*METHODS@#Fifteen edentulous patients were randomly recruited by three prosthodontists who passed the unified operating process training. The custom trays for each patient were fabricated using both chair-side CAD/3DP system of independent development and manually conventional method, and the final impressions were made by silicone impression materials (light body). The prosthodontist's satisfaction was surveyed by the three prosthodontists via the questionnaire based on visual analogue scales.@*RESULTS@#In the degree of the prosthodontist's satisfaction of final impressions, the average satisfactions of "try in" (the overall size, shape, convenience, etc.) on the 3DP custom tray made by independent development chair-side system and the manually conventional method were 9.18±0.19 and 8.23±0.22, respectively. The average satisfactions of the border line position (border extensions, frenal notch)were 8.91±0.40 and 7.96±0.23, respectively. The average satisfactions of the stability in border molding were 8.80±0.83 and 8.01±0.81, respectively. The average satisfactions of the quality of final impression (completeness, thickness of impression material, exposure of custom tray, shape of border) were 8.94±0.68 and 7.99±0.42, respectively. The average satisfactions of the difficulty of high quality impression (times of repetition, efficiency) were 9.20±0.37 and 7.88±0.22, respectively. The average satisfactions of the overall satisfaction were 9.11±0.49 and 7.95±0.15, respectively. There was significant difference in the satisfaction of "try in", border line position, stability in border molding, quality of final impression, difficulty of high quality impression, and overall satisfaction between the 3DP custom tray made by chair-side system of independent development and the manually conventional method (P<0.05).@*CONCLUSION@#In the degree of the prosthodontist's satisfaction of final impression, the 3DP custom tray made by chair-side system of independent development is higher than that of the conventional custom tray, and it meets the clinical requirements and can be popularized in clinical application.


Subject(s)
Humans , Computer-Aided Design , Dental Impression Materials , Dental Impression Technique , Mouth, Edentulous , Printing, Three-Dimensional
20.
Journal of Peking University(Health Sciences) ; (6): 335-339, 2019.
Article in Chinese | WPRIM | ID: wpr-941816

ABSTRACT

OBJECTIVE@#To explore a novel method for fabricating removable partial dentures (RPDs) using polyetheretherketone (PEEK) by computer-aided design and computer-aided manufacturing (CAD/CAM) technologies and to evaluate their fits for different assemblies in vitro.@*METHODS@#A standard stone cast of mandibular partial edentulous jaw was scanned using a lab scanner. Based on the digital cast, thirteen complete RPDs were designed combing dental CAD software and reverse engineering software, and then fabricated using PEEK by milling machine. Fits of assemblies were evaluated quantitatively by measuring the spaces between RPDs and casts. The gaps between RPDs and stone casts in different assemblies were duplicated using light-body silicone impression material and then measured using three-dimensional (3D) digital analysis methods in virtue of a dedicated software. Statistically, one-way analysis of variance (ANOVA) was used to compare the difference of gaps among assemblies in different shapes such as occlusal rest, denture base, and major connector. Paired-samples t test was used to compare the gaps difference for the similar shape assemblies in different areas.@*RESULTS@#One-piece PEEK RPDs were successfully designed and fabricated by CAD/CAM, and all the RPDs were well-seated on stone casts. The gaps between occlusal rests and casts [(84.3±23.6) μm] were significantly larger than those of denture bases [(32.5±27.8) μm] and major connectors [(49.9±47.0) μm], which meant that the fits of denture bases and major connectors were better than that of occlusal rests. However, the fits of all assemblies could be accepted clinically. For the similar shape assemblies in different areas, there were no significantly differences for gaps between distal extension denture bases [(25.1±55.3) μm] and non-extensive denture bases [(41.5±17.7) μm]. The gaps of occlusal rests adjacent and nonadjacent to the edentulous space were (86.1±29.8) μm and (80.8±42.1) μm respectively and there were no significantly difference between them either. These results implied that different locations had no apparent effect on the fits of assemblies.@*CONCLUSION@#With the computer-aided design and computer-aided manufacturing technology, PEEK can be used to fabricate one-piece removable partial dentures. And all assemblies of the one-piece PEEK RPDs showed satisfying fits in vitro, indicating a promising clinical application in the future.


Subject(s)
Benzophenones , Computer-Aided Design , Denture, Partial, Removable , Ketones , Polyethylene Glycols , Polymers
SELECTION OF CITATIONS
SEARCH DETAIL